Utilities is currently updating standard details and the official design manual for engineers, consultants, and contractors.  Design Manual CD Information.

New Specifications
1 Pump Station and Force Main Policies and Specifications

New Standard Details - more details will be posted here.  The following Standard Details are new or have been revised. 

Please replace old details with current versions, based on subject matter (not Section Name or Number), as updated Section Names or Chapter Numbers may have changed.  The most recent/current versions will be maintained on this site.  Designers and Contractors shall be required to use the current posted version which supersedes any and all prior versions.

The most recent/current  versions will be maintained at this site.  Designers and Contractors shall be required design and construct projects based on the current posted version which supersedes any and all prior versions.

Printing Tips: The Standard Details were developed for printing on Tabloid (11" x 17") size paper.  They may be printed on Tabloid (11" x 17") or Legal (8.5" x 14") size paper and retain sufficient detail and text size to remain useful.  We do not recommend printing on Letter (8.5" x 11")  size paper. Remember to un-check the " Choose paper source by page size" check box when printing to any size other than Tabloid.  You may also need to select "Fit to Printable Area" in the Page Scaling drop down box.

Water Standard Details
     Irrigation Services
     New Construction
     Cross Connection / Backflow Protection
     Water Rehabilitation

Sanitary Sewer Details (coming later this year)
     Gravity Sewer
     Pump Station and Force Mains
     Low Pressure Sewers
     Sewer Rehabilitation


Water Standard Details
A    Auto Flusher On Fire Hydrant
B    Auto Flusher On 2-Inch Blow Off
C   Backside Tapping Sleeve And Valve On 16-Inch And Smaller Mains
D1  Service Saddle Cathodic Protection On Pvc Mains - Part 1
D2  Service Saddle Cathodic Protection On Pvc Mains - Part 2
D3  Service Saddle Cathodic Protection On Pvc Mains - Part 3
E 3-inch Compound Water Meter & Vault
F 4-inch Compound Water Meter & Vault
G New Water Main Jumper Schematic 2"-24" Mains

Irrigation Services
A 3/4-inch plastic meter box
B 3/4 to 1-inch backflow at house
3/4 to 1-inch backflow at road 
D 1-inch plastic meter box (not yet approved) - use 1-inch standard concrete box with plastic lid.
E 3/4-inch plastic meter box in concrete sidewalk

1 Split Irrigation Service (backflow at house, dual check at meter)
2 Split Irrigation Service (backflow at road, no dual check at meter)
3 Dedicated Irrigation Service (backflow at house, dual check at meter)
Dedicated Irrigation Service (backflow at road, no dual check at meter)

New Construction (more coming later this year)
12B Standard Detail Water Jumper Connection with Backflow Preventer (See Water Standard Detail G above)
17 Standard Detail Water 3/4 and 1 inch water service connection
18 Standard Detail Water concrete meter box 3/4-inch water meter
19 Standard Detail Water concrete meter box 1-inch water meter
20 Standard Detail Water fire line connection
21 Standard Detail Water frame and cover 2'x3'
22 Standard Detail Water 3"x4" meter (See Water Standard Details E and F above)
23 Standard Detail Water frame and cover 4'x5'
24 Standard Detail Water 6"x8" meter
25 Standard Detail Water frame and cover 5'x5'
26 Standard Detail Water 10"x6", 10"x12"x6" meter
27 Standard Detail Water 1 1/2" & 2" meter setter
28 Standard Detail Water frame and cover 6'x4' meter
29 Standard Detail Water Lowering 6 - 12-inch Water Mains

Cross Connection / Backflow Protection
additional details posted on Backflow Protection page.


Water Rehabilitation


Sanitary Sewer Details (more coming later this year)
Gravity Sewer

A Type 1 24-inch Manhole Cover vented.pdf
B Type 2 24-inch Manhole Cover solid.pdf
C Type 3 24-inch Manhole Cover watertight.pdf
D Type 4 30-inch Manhole Cover vented.pdf
E Type 5 30-inch Manhole Cover watertight.pdf

F Type A 24-inch Manhole Frame 7 1/2-inch tall.pdf
G Type B 24-inch Manhole Frame 4-inch tall.pdf
H Type C 24-inch Manhole Frame 4-inch tall inverted / reversible.pdf
J Type D 30-inch Manhole Frame 4-inch tall.pdf
K Type E 30-inch Manhole Frame 4-inch tall inverted / reversible.pdf

Pump Station and Force Mains
Pump Station and Force Main Policies and Specifications

1 Combination Air and Vacuum Valve


Low Pressure Sewers
1 Standard Detail Pressure Sewer - Valve Detail at Intersection

Sewer Rehabilitation (coming later)