Mecklenburg County, LUESA Storm Drainage As-Built Requirements

Storm Drainage As-Built plans are required before subdivisions receive final inspection approval and before Water Quality BMP"s are approved

Three copies of plans must be signed and sealed by a Professional Land Surveyor and submitted to LUESA for approval. Mylars are not required.

Storm Drainage Pipe and Inlet Information

  • Slopes
  • Pipe length and size
  • Pipe material
  • Pipe location, if different from plan
  • Inlet rim elevations
  • Invert elevations
  • Verify special requirements (such as Class IV pipe or o-ring joints)

Storm Drain Ditch Information

  • Typical cross-section for all designed ditches. Indicate location of changes if cross section varies from the typical

Storm Drainage BMP"S (Water Quality Ponds)

  • Actual topography elevations of the pond, including what is underwater
  • Elevations of all outlet structures
  • Size of all discharge features
  • Verify existence of drawn-down valves, when required
  • Spillway and weir cross-sections

Post Construction Requirements

Common Reasons for Disapproval

  • No Land Surveyor Seal
  • Pipe is less than .5% slope
  • The velocity at a discharge point is 10 fps or greater (greater than 5 fps on more recent projects)
  • Pipe slope differs greatly from design
  • There is less than 2 feet + the pipe diameter from the invert to the rim of a drainage structure in the street. If this happens, be sure Class IV RCP pipe was used.
  • The volume of the BMP is undersized
  • The BMP aquatic shelf is not within 1 to 1.5 feet below the permanent pool elevation
  • There is no access point or safety bench for equipment to get to the BMP when it needs maintenance
  • Outlet devices are not sized according to plans