1) What would be the net calculated load in volt amps of a dwelling unit with a floor area of 1500 sq. ft. including an unfinished cellar not adaptable for future use, unfinished attic, and open porches. Appliances are a 12-KW range and a 5.5-KW, 240-V dryer. Assume range and dryer KW ratings equivalent to KVA ratings in accordance with 220.54 and 220.55.
a) 17,600 VA
b) 17,100 VA
c) 18,600 VA
d) 18,100 VA
See Answer
2) How many outdoor convenience outlets excluding the A/C units are required for a dwelling unit that is 4867 sq. ft. with a detached garage on a quarter acre corner lot?
a) one
b) two
c) three
d) none
See Answer
3) How many 15 amp general use circuits are required for a single family dwelling unit 3120 square feet that has a full kitchen, 2 bathrooms, a living room, and 4 bedrooms each with a walk in closet?
a) 2 circuits
b) 4 circuits
c) 5 circuits
d) 6 circuits
See Answer
4) Which of the following locations are you not allowed to install overcurrent devices?
a) Hallways
b) Bedrooms
c) Clothes closet
d) Storage room
See Answer
5) All of the outlets in a single family bedroom are required by the NEC to be protected by arc-fault devices. Which of the following items are not required to be protected by arc-fault devices?
a) Switch for exterior flood lights
b) Ceiling fan
c) Wall outlets
d) Lighting fixtures
See Answer